Top Searches:PM2.5 sensor/dust sensor Ultraviolet Sensor Water Quality Sensor gas mass flow sensor Acceleration sensor/transmitter Hall sensor/Hall position sensor Temperature and humidity module/probe Temperature and humidity digital output module humidity-sensitive capacitive sensor humidity sensitive resistance sensor Temperature and humidity transmitter/instrument infrared temperature sensor electrochemical gas sensor semiconductor gas sensor PPM grade micro oxygen sensor NDIR Gas Sensor catalytic combustion gas sensor Zirconia Sensor Level Sensor LLC Series Ultrasonic liquid level sensor fiber optic signal conditioner optical fiber pressure sensor fiber optic strain sensor Pressure sensor with digital output Silicon etching technology full range of pressure sensors infrared emitting diode Photoelectric crystal (receiving tube)
  • Current Location:Home > Product > Gas Sensors/Gas Transmitters > electrochemical gas sensor
  • electrochemical gas sensor

    Dual gas sensor/carbon monoxide/hydrogen sulfide sensor D2

    Product Model:D2

    Brand: British Alpha Alphasense

    Product Category: electrochemical gas sensor



    Double gas carbon monoxide/hydrogen sulfide sensor D2
    -- Small size

    Introduction of 1. double gas carbon monoxide/hydrogen sulfide sensor D2:
    The D2 sensor provides a unique method in terms of external dimensions and electrode structure. The use of a high-capacity filter on the working electrode of carbon monoxide can completely eliminate the cross-sensitivity of the channel to hydrogen sulfide, acid gas and similar sulfur dioxide and nitrogen oxides. The use of D2 series sensors in portable instrument design can use composite gases to achieve accurate factory-level maintenance-level and field-level calibration without worrying about incorrect adjustment of CO channels.

    Technical indicators of the carbon monoxide channel of the 2. D2 type sensor:
    Resolution: 1ppm
    Response time t90 (seconds)<25s
    Measuring range: 1000 ppm
    Zero current Performance Sensitivity: 27-55nA/ppm @ 22C, 400ppm CO
    Linearity:<40ppm/Linearity error at full range (zero, 400ppm)
    Overload range: 5,000ppm/max concentration of stable response gas pulse

    Technical specifications of the hydrogen sulfide channel of the 3. D2 sensor:
    Resolution:<0.25ppm
    Response time t90 (seconds)<30s
    Measuring range: 100 ppm
    Zero current Performance Sensitivity: 90-175nA/ppm @ 22C, 20ppm H2S
    Linearity: Linearity error at 0 ~-9ppm/full range (zero, 20ppm)
    Overload range: 400ppm/max concentration of stable response gas pulse