Shenzhen Jiesheng Xing Electronics Co., Ltd.We offer complete sensor solutions

Hotline:13662266995
Top Searches:PM2.5 sensor/dust sensor Ultraviolet Sensor Water Quality Sensor gas mass flow sensor Acceleration sensor/transmitter Hall sensor/Hall position sensor Temperature and humidity module/probe Temperature and humidity digital output module humidity-sensitive capacitive sensor humidity sensitive resistance sensor Temperature and humidity transmitter/instrument infrared temperature sensor electrochemical gas sensor semiconductor gas sensor PPM grade micro oxygen sensor NDIR Gas Sensor catalytic combustion gas sensor Zirconia Sensor Level Sensor LLC Series Ultrasonic liquid level sensor fiber optic signal conditioner optical fiber pressure sensor fiber optic strain sensor Pressure sensor with digital output Silicon etching technology full range of pressure sensors infrared emitting diode Photoelectric crystal (receiving tube)
  • Current Location:Home > Product > Gas Sensors/Gas Transmitters > semiconductor gas sensor
  • semiconductor gas sensor

    p-type metal oxide VOC sensor VOC-A31 M31 P31

    Product Model:VOC-A31 M31 P31

    Brand: British Alpha Alphasense

    Product Category: semiconductor gas sensor



    A p-type metal oxide VOC sensor VOC-A31 M31 P31 product introduction

    This sensor is a broadband Total Volatile Organic Compounds (Total VOC) detector. When considering the cost of PID, the sensor can be used to detect 10 to 50ppb of VOC, depending on the type of VOC. Unlike common n-type sensors, this metal oxide sensor has a large dynamic range, a repeatable response, is less affected by humidity, and will increase resistance to most VOCs.

    The sensor is available in 3 housings: TO-05 housing, 6-pin plastic housing and Ex explosion-proof housing.


    Two p-type metal oxide VOC sensor VOC-A31 M31 P31 main features

    1) Range: 1-100ppm isobutylene

    2) Sensor resistance (R0):210 ±30 kΩ (50% rh, 23 (± 2)℃)

    3) Sensor resistance (Rg):550 ±50 kΩ (isobutylene @ 10ppm<< span = ""> in air>)

    4) Sensor resistance ratio (Rg/ R0 * 100%):260 ±30% (isobutylene @ 10ppm<< span = ""> in air>)

    5) gas response relation (Rg/Ro - 1 = σ ki x Concn) : 0.5 +/- 10% (k for isobutylene)

    where Ki = constant for gas I; n = 1 or 0.5: 0.5 (n for isobutylene))

    6) Heater resistance (RH @ RT):10 ±1.5 Ω (23±1 ℃)

    7) Heater resistance (RH @ sensing temperature):22 ±3 Ω (400±10 ℃)

    8) Heater resistance (RH @ reset temperature):26 ±3 Ω (525±10 ℃)

    9) Typical heating power consumption (mW) at 5:1 cycle: 340 ±30 (400 ℃) (VH = 2.7 ±0.2V)

    530 ±50 (525℃)(VH = 3.7 ±0.3V)

    10) Working temperature:-20~120 ℃

                       




    Previous Page: Hydrogen sensor TGS2615-E00
    Next page: Air Quality Sensor TGS2603


    Online Inquiry