Shenzhen Jiesheng Xing Electronics Co., Ltd.We offer complete sensor solutions

Hotline:13662266995
Top Searches:PM2.5 sensor/dust sensor Ultraviolet Sensor Water Quality Sensor gas mass flow sensor Acceleration sensor/transmitter Hall sensor/Hall position sensor Temperature and humidity module/probe Temperature and humidity digital output module humidity-sensitive capacitive sensor humidity sensitive resistance sensor Temperature and humidity transmitter/instrument infrared temperature sensor electrochemical gas sensor semiconductor gas sensor PPM grade micro oxygen sensor NDIR Gas Sensor catalytic combustion gas sensor Zirconia Sensor Level Sensor LLC Series Ultrasonic liquid level sensor fiber optic signal conditioner optical fiber pressure sensor fiber optic strain sensor Pressure sensor with digital output Silicon etching technology full range of pressure sensors infrared emitting diode Photoelectric crystal (receiving tube)
  • Current Location:Home > Product > Gas Sensors/Gas Transmitters > semiconductor gas sensor
  • semiconductor gas sensor

    P-Type Metal Oxide CO Sensor CO-A31/F M31/F P31/F

    Product Model:CO-A31/F M31/F P31/F

    Brand: British Alpha Alphasense

    Product Category: semiconductor gas sensor



    A P-type metal oxide CO sensor CO-A31/F M31/F P31/F Product Introduction

    The metal oxide sensor can work well in ambient conditions and also in extreme temperature and humidity environments that electrochemical sensors cannot handle. The sensor is equipped with a filter that is selective for CO. Unlike the common n-type sensor, the metal oxide sensor has a large dynamic range, a repeatable response, little influence by humidity, and an increase in resistance when exposed to CO.

    The sensor is available in 3 housings: TO-05 housing, 6-pin plastic housing and Ex explosion-proof housing.



    Two p-type metal oxide CO sensor CO-A31/F M31/F P31/F main characteristics

    1) Range: 5-500ppm CO

    2) Sensor resistance (R0):135±25 kΩ (50% rh, 23 (± 2)℃)

    3) Sensor resistance (Rg):160 ±10 kΩ (CO @ 10ppm<< span = ""> in air>)

    4) Sensor resistance ratio (Rg/ R0 * 100%):120 ±3% (CO @ 10ppm<< span = ""> in air>)

    5) Gas response relation (Rg/Ro - 1 = k.Conc) : 0.01 ±10%(5-50ppm)

    Gas response relation (Rg/Ro - 1 = k.Conc0.5): 0.08 ±15%(5-500ppm)

    6) Heater resistance (RH @ RT):10 ±1.5 Ω (23±1 ℃)

    7) Heater resistance (RH @ sensing temperature):22 ±3 Ω (400±10 ℃)

    8) Heater resistance (RH @ reset temperature):26 ±3 Ω (525±10 ℃)

    9) Typical heating power consumption (mW) at 5:1 cycle: 340 ±30 (400 ℃) (VH = 2.7 ±0.2V)

    530 ±50 (525℃)(VH = 3.7 ±0.3V)

    10) Working temperature:-20~120 ℃

                       




    Previous Page: Alcohol sensor TGS2620
    Next page: Methane gas pre-calibration module FSM-T-01


    Online Inquiry