
p-type metal oxide H2S sensor H2S-A31 M31 P31
Brand: British Alpha Alphasense
Product Category: semiconductor gas sensor
A P-type metal oxide H2S sensor H2S-A31 M31 P31 product introduction
The sensor responds well in the extreme humidity and temperature environments of the oil and gas industries and is equipped with an integrated filtration unit that makes it selective for H2S. Unlike common n-type sensors, this metal oxide sensor has a large dynamic range, a repeatable response, little humidity effect, and an increased resistance to H2S.
The sensor is available in 3 housings: TO-05 housing, 6-pin plastic housing and Ex explosion-proof housing.
Two p-type metal oxide H2S sensor H2S-A31 M31 P31 main characteristics
1) Range: 1-100ppm H2S
2) Sensor resistance (R0):220±50 kΩ (50% rh, 23 (± 2)℃)
3) Sensor resistance (Rg):1900 ±500 kΩ (H2S @ 24ppm<< span = ""> in air>)
4) Sensor resistance ratio (Rg/ R0 * 100%):860 ±250% (H2S @ 24ppm<< span = ""> in air>)
5) Gas response relationship (Rg/Ro - 1 = k.Conc): 0.30±0.09 ppm-1 (5 - 30 ppm)
Gas response relationship (Rg/Ro - 1 = k.Conc): 0.24±0.07 ppm-1 (30 - 100 ppm)
6) Heater resistance (RH @ 23±1 ℃):10 ±1.5 Ω
7) Heater resistance (RH @ 400 ±10 ℃):22 ±3 Ω
8) Heater resistance (RH @ 525±10 ℃):26 ±3 Ω
9) Heater power consumption (mW): 340±30 (400 ℃) (VH = 2.7 ±0.2V)
530 ±50 (525℃)(VH = 3.7 ±0.3V)
10) Working temperature:-20~120 ℃
Previous Page: Methane gas pre-calibration module FSM-T-01
Next page: Halogen gas sensor TGS832-A00
Shenzhen Jiesheng Xing Electronics Co., Ltd.


