Top Searches:PM2.5 sensor/dust sensor Ultraviolet Sensor Water Quality Sensor gas mass flow sensor Acceleration sensor/transmitter Hall sensor/Hall position sensor Temperature and humidity module/probe Temperature and humidity digital output module humidity-sensitive capacitive sensor humidity sensitive resistance sensor Temperature and humidity transmitter/instrument infrared temperature sensor electrochemical gas sensor semiconductor gas sensor PPM grade micro oxygen sensor NDIR Gas Sensor catalytic combustion gas sensor Zirconia Sensor Level Sensor LLC Series Ultrasonic liquid level sensor fiber optic signal conditioner optical fiber pressure sensor fiber optic strain sensor Pressure sensor with digital output Silicon etching technology full range of pressure sensors infrared emitting diode Photoelectric crystal (receiving tube)
  • Current Location:Home > Product > Gas Sensors/Gas Transmitters > semiconductor gas sensor
  • semiconductor gas sensor

    p-type metal oxide H2S sensor H2S-A31 M31 P31

    Product Model:H2S-A31 M31 P31

    Brand: British Alpha Alphasense

    Product Category: semiconductor gas sensor



    A P-type metal oxide H2S sensor H2S-A31 M31 P31 product introduction

    The sensor responds well in the extreme humidity and temperature environments of the oil and gas industries and is equipped with an integrated filtration unit that makes it selective for H2S. Unlike common n-type sensors, this metal oxide sensor has a large dynamic range, a repeatable response, little humidity effect, and an increased resistance to H2S.

    The sensor is available in 3 housings: TO-05 housing, 6-pin plastic housing and Ex explosion-proof housing.


    Two p-type metal oxide H2S sensor H2S-A31 M31 P31 main characteristics

    1) Range: 1-100ppm H2S

    2) Sensor resistance (R0):220±50 kΩ (50% rh, 23 (± 2)℃)

    3) Sensor resistance (Rg):1900 ±500 kΩ (H2S @ 24ppm<< span = ""> in air>)

    4) Sensor resistance ratio (Rg/ R0 * 100%):860 ±250% (H2S @ 24ppm<< span = ""> in air>)

    5) Gas response relationship (Rg/Ro - 1 = k.Conc): 0.30±0.09 ppm-1 (5 - 30 ppm)

    Gas response relationship (Rg/Ro - 1 = k.Conc): 0.24±0.07 ppm-1 (30 - 100 ppm)

    6) Heater resistance (RH @ 23±1 ℃):10 ±1.5 Ω

    7) Heater resistance (RH @ 400 ±10 ℃):22 ±3 Ω

    8) Heater resistance (RH @ 525±10 ℃):26 ±3 Ω

    9) Heater power consumption (mW): 340±30 (400 ℃) (VH = 2.7 ±0.2V)

    530 ±50 (525℃)(VH = 3.7 ±0.3V)

    10) Working temperature:-20~120 ℃