The continuous high temperature in summer can not help but remind people of ancient timesThe fear of being dominated by ten suns, no WIFI, no watermelon, and the most terrible thing is that there is no air conditioner!
Speaking of air conditioning, at present, the refrigerant widely used in air conditioning equipment is chemically stable and non-flammable (AI) Freon. Therefore, even if the refrigerant leaks to the outside of the air conditioning equipment, there is no need to worry about safety issues such as fire. However, non-combustible (AI) Freon has been clearly caused by the warming of the greenhouse gas. If a large amount of leakage escapes, it will aggravate the greenhouse effect and cause the earth to be hotter.

For this reason, it has been put on the agenda to replace it with weak flammable (A2L) refrigerants with smaller warming coefficient (GWP). However, the weak flammable refrigerant still has a certain degree of combustion, in case of leakage, there is still the possibility of fire. In order to reduce the above risks, it is necessary to install a gas sensor for leak detection for air conditioning equipment or refrigeration equipment that uses a weak flammable (A2L) refrigerant and reaches a certain amount.

Gas detection methods suitable for weak flammable (A2L) refrigerant detection include semiconductor gas sensors and infrared (NDIR) gas sensors.
The NDIR gas sensor is characterized by good selectivity for the target gas and high detection accuracy. Therefore, it is very suitable for the detection of refrigerant leakage in large-scale frozen warehouses and refrigeration equipment. Meanwhile, as compared with a semiconductor-type gas sensor, the output may be irreversibly changed when it is subjected to mechanical vibration or impact, and the optical system may be defaced when it is used in a dust-polluted environment for a long period of time, resulting in a decrease in the output. It is necessary to fully consider the shortcomings of its high cost and excessive size.

To this end, FIGARO developed a new refrigerant detection sensor TGS2630. It is not only widely used in the detection of air conditioning, refrigeration equipment, the most commonly used refrigerant R-404a, R-410a, to reduce the GWP (global warming index) "weak flammable (A2L) refrigerant" R-32, R-1234yf and "flammable (A3) refrigerant" R-290 (the main component of propane) also has a high sensitivity.

Refrigerant gas detection sensor TGS2630

Sensitivity characteristics of refrigerant gas detection sensor TGS2630
TGS2630Has the following characteristics:
* to the weak combustible“A2L”and flammable“A3”RefrigerationHigh sensitivity of the agent
* Selectivity has been greatly improved
* Simple application circuit
* Low power consumption
At the same time, in order to reduce the interference of volatile organic gases such as alcohol in the living environment, a filter layer has been added to the interior, makingTGS2630sensitivity to these organic volatile gases is low, and therefore,TGS2630It is very suitable for leak detection of new refrigerants.
Please consult for details.
Previous Page: Application of Oxygen Sensor in Chemical Plant
Next page: Application of hydrogen detector in hydrogen leak detection
Shenzhen Jiesheng Xing Electronics Co., Ltd.