Top Searches:PM2.5 sensor/dust sensor Ultraviolet Sensor Water Quality Sensor gas mass flow sensor Acceleration sensor/transmitter Hall sensor/Hall position sensor Temperature and humidity module/probe Temperature and humidity digital output module humidity-sensitive capacitive sensor humidity sensitive resistance sensor Temperature and humidity transmitter/instrument infrared temperature sensor electrochemical gas sensor semiconductor gas sensor PPM grade micro oxygen sensor NDIR Gas Sensor catalytic combustion gas sensor Zirconia Sensor Level Sensor LLC Series Ultrasonic liquid level sensor fiber optic signal conditioner optical fiber pressure sensor fiber optic strain sensor Pressure sensor with digital output Silicon etching technology full range of pressure sensors infrared emitting diode Photoelectric crystal (receiving tube)
  • Current Location:Home > Solution
  • Application of optical micro oxygen sensor LOX-TRACE-1000-BLX in glove box

    The glove box is a laboratory equipment that fills the box with high-purity inert gas and circulates and filters out the active substances in the box. Also known as inert gas protection box, drying box, etc. Mainly used to removeO2, H2O and organic gases, widely used in anhydrous, oxygen-free, dust-free ultra-pure environment.

     

    The working gas in the glove box is under the control and monitoring of the programmable controller,and gas purification system to form a closed circulation systemPurification system using renewable/Reduced purification material, the reduction procedure is automatically controlled by the system,When the working gas is circulated through the purification system, the moisture and oxygen contained therein are absorbed and then returned to the tank. With the extension of the cycle time, the moisture and oxygen content in the working gas in the box gradually decreased, and zui finally reached the target value of the set oxygen content. After a period of circulation, the moisture and oxygen of the working gas of the box body reach below the set index, and can be regenerated and reused.

     

    Some substances are easily oxidized and deliquesced in the atmosphere, which makes the chemical reaction of the test substance and the pre-treatment of the sample very difficult, which affects the test process and test results. The glove box can be isolated from the air for experiments. For example, lithium metal reacts with oxygen, and some reactions need to be carried out in an inert gas such as argon. The glove box can use lead and lead glass to protect the operator from toxic chemicals.

     

    Installing the oxygen sensor in the glove box can monitor the oxygen content in the glove box in real time, and display the current content on the touch screen, which can realize the interlocking of the oxygen sensor with the circulating fan and purifier in the glove box, realize continuous deaeration when the oxygen content is high, and maintain the test or production conditions.

     

    United KingdomSST fluorescent micro oxygen transmitter-LOX-TRACE-1000-BLX can be exposed to any oxygen concentration environment and is highly selective and sensitive to oxygen, without damaging the sensor, and has fast response speed and short purification time. It is connected to the controller through RS485 interface.

     

         SST Fluorescent Micro Oxygen Transmitter

    United KingdomSST fluorescent micro oxygen transmitter related electrical and performance parameters

    Range

    0-1000PPM

    Resolution

    1PPM

    Working pressure range

    260mbar-1260mbar

    High precision

    Response time

    T90

    Working voltage and current

    8-30VDC Average Current:

    Output signal

    RS485 Modbus RTU

    Working temperature

    -10℃ ~ +40℃

    Storage temperature

    -30℃ ~ +50℃

    Life

    More than 5 years